Product name : MTP1 Delay Reset Thermostat
KEY BENEFITS:
Diamond shape, small size
Good pressure resistance
Rapid response to high-sensitive temperature and current
Rapid response
Protect on the safe side(cutoff lock self, reset after break down)
Using scope:
Applies to the AC motor, coils, electromagnets, Water boilers, DC motor, generator, solar water heater, hot air driers, liquid pumps, transformers and similar household electrical appliances.
Key Technical Parameters:
Rated voltage: 50/60HZ, 250V, AC
Nominal current: 2.5 (1.6) A,/10 (6.3) A ,COSФ =1.0 (0.6)
Rated opening temperature range: +60 ℃ ~+160 ℃, take 5 ℃ as a grade
Type |
TP1 |
||
Rated Voltage:50/60HZ |
220-250V |
||
Rated Current AC Max.load |
COSΦ=1.0 |
2.5A |
10.0A |
COSΦ=0.6 |
1.6A |
6.3A |
|
250V 50/60HZ |
6.3A |
16A |
|
110V 50/60HZ |
10.0A |
36.0A |
|
DC Max.load |
60V |
1.0A |
4.0A |
42V |
1.2A |
4.8A |
|
6V 12V 24V |
1.5A |
6.0A |
|
Contact arrangement |
Normally Closed |
||
Rated Open temp.range |
+60℃~+160℃,In steps of 5℃ |
||
Tolerance |
±5℃ |
||
Resetting temperature |
Under normal temp. circumstance, reset after break down |
||
Contact resistance |
≤50mΩ |
||
Proof tracking index |
PT1 175 |
||
For protection class |
ClassⅠ |
||
Insulation class |
IP00 |
||
Automatic action |
Type 3 action |
||
Pressure stability of housing |
100N |
||
Vibration proof at 10-60Hz |
10 m/s² |
||
Dielectric Strength |
AC 1500V 50/60HZ 1MIN |
||
Standard connection |
0.2 to 0.75mm2 (24AWG to 18AWG) |
||
Case material |
Stainless steel |
||
Switching cycles at In |
300 cyles |
||
Length of shrinking cap |
22±2mm |